Commercial Storage
241 kWh All-in-One ESS
All-in-one cabinet energy storage system, 241.15 kWh, 100 kW PCS
- 241.15 kWh
- 100 kW
- ≥ 6,000 cycles
View details
Commercial Energy Storage
Liquid-cooled cabinet energy storage system with 125 kW hybrid inverter
A 261 kWh liquid-cooled cabinet with a built-in 125 kW hybrid inverter, expandable to 15.66 MWh.
This commercial energy storage cabinet uses advanced 314 Ah LFP cells and a patented liquid-cooling design at pack level for consistent temperatures from cell to cell. A 125 kW hybrid inverter is built in, with zero heat transfer between the inverter and the cells for stability and a longer life. It switches from on-grid to off-grid in under 10 ms, expands up to 1.25 MW / 15.66 MWh, and supports remote monitoring and OTA upgrades through the JUN-HAN StorageCloud app.
| Rated energy capacity | 261 kWh |
|---|---|
| Usable energy capacity | 235 kWh |
| Max. cycle rate | 0.5P |
| Max. cycle efficiency | 90% |
| Dimensions (W × H × D) | 1500 × 1400 × 2250 mm |
| Dimensions without inverter (W × H × D) | 1060 × 1400 × 2250 mm |
| Weight | 2500 kg (cabinet) + 170 kg (inverter) |
| Temperature control | Industrial-grade air-conditioning (cabinet); liquid cooling (pack); intelligent fan cooling (inverter) |
| Fire suppression | Default: aerosol, explosion relief valve, fire water inlet. Optional: flammable gas detector, explosion relief panel, explosion-proof exhaust fan, audible and visual alarm |
| Ingress protection | IP54 (cabinet), IP66 (inverter) |
| Anti-corrosion class | Battery C4/C5 (optional); inverter C5 |
| Noise | 75 dB at 1 m |
| Lightning protection | Type II (AC port), Type II (PV and battery) |
| Protection | Anti-islanding, residual current detection, insulation resistance detection, AC overcurrent protection and AC cable connection protection |
| Certification | IEC 62619, IEC 61000-6-2/4, IEC 62040, IEC 63056, IEC 62477, UN38.3 |
| Cell type | LFP 3.2 V / 314 Ah |
|---|---|
| Cell cycle life | 6000 |
| System battery configuration | 1P260S |
| Rated voltage | 832 V |
| Operating voltage range | 728 V to 936 V |
| Rated DC current | 157 A |
| Number of battery packs | 5 |
| Battery pack capacity | 52.25 kWh |
| Battery pack weight | 340 kg |
| Rated output power | 125 kW |
|---|---|
| Max. apparent output power (on-grid) | 125 kVA |
| Max. apparent output power (off-grid) | 1.6 × rated power, 200 ms |
| Rated grid voltage | 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| AC grid frequency range | 45 Hz to 55 Hz / 55 Hz to 65 Hz |
| Rated output current | 189.9 A / 180.4 A |
| Back-up switch time | < 10 ms |
| Power factor | > 0.99 (0.8 leading to 0.8 lagging) |
| THDi / THDv (linear load) | < 2% / < 3% |
| Max. usable PV input power | 250 kW |
|---|---|
| Recommended max. PV array size | 250 kW |
| Max. input voltage | 1000 V |
| Rated voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT voltage range | 150 V to 950 V |
| Max. input current | 10 × 42 A |
| Max. short circuit current | 10 × 60 A |
| MPPT number / max. input strings | 10 / 20 |
| Operating temperature | -25 °C to 55 °C |
|---|---|
| Max. operating altitude | 3000 m |
| Operating humidity | ≤ 95% (non-condensing) |
| Communication | CAN, RS485-115200, Ethernet. Optional: Wi-Fi, cellular, LAN |
|---|
| Rated energy capacity | 261 kWh |
|---|---|
| Usable energy capacity | 235 kWh |
| Max. cycle rate | 0.5P |
| Max. cycle efficiency | 90% |
| Dimensions (W × H × D) | 1500 × 1400 × 2250 mm |
| Dimensions without inverter (W × H × D) | 1060 × 1400 × 2250 mm |
| Weight | 2500 kg (cabinet) + 170 kg (inverter) |
| Temperature control | Industrial-grade air-conditioning (cabinet); liquid cooling (pack); intelligent fan cooling (inverter) |
| Fire suppression | Default: aerosol, explosion relief valve, fire water inlet. Optional: flammable gas detector, explosion relief panel, explosion-proof exhaust fan, audible and visual alarm |
| Ingress protection | IP54 (cabinet), IP66 (inverter) |
| Anti-corrosion class | Battery C4/C5 (optional); inverter C5 |
| Noise | 75 dB at 1 m |
| Lightning protection | Type II (AC port), Type II (PV and battery) |
| Protection | Anti-islanding, residual current detection, insulation resistance detection, AC overcurrent protection and AC cable connection protection |
| Certification | IEC 62619, IEC 61000-6-2/4, IEC 62040, IEC 63056, IEC 62477, UN38.3 |
| Cell type | LFP 3.2 V / 314 Ah |
|---|---|
| Cell cycle life | 6000 |
| System battery configuration | 1P260S |
| Rated voltage | 832 V |
| Operating voltage range | 728 V to 936 V |
| Rated DC current | 157 A |
| Number of battery packs | 5 |
| Battery pack capacity | 52.25 kWh |
| Battery pack weight | 340 kg |
| Rated output power | 125 kW |
|---|---|
| Max. apparent output power (on-grid) | 125 kVA |
| Max. apparent output power (off-grid) | 1.6 × rated power, 200 ms |
| Rated grid voltage | 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| AC grid frequency range | 45 Hz to 55 Hz / 55 Hz to 65 Hz |
| Rated output current | 189.9 A / 180.4 A |
| Back-up switch time | < 10 ms |
| Power factor | > 0.99 (0.8 leading to 0.8 lagging) |
| THDi / THDv (linear load) | < 2% / < 3% |
| Max. usable PV input power | 250 kW |
|---|---|
| Recommended max. PV array size | 250 kW |
| Max. input voltage | 1000 V |
| Rated voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT voltage range | 150 V to 950 V |
| Max. input current | 10 × 42 A |
| Max. short circuit current | 10 × 60 A |
| MPPT number / max. input strings | 10 / 20 |
| Operating temperature | -25 °C to 55 °C |
|---|---|
| Max. operating altitude | 3000 m |
| Operating humidity | ≤ 95% (non-condensing) |
| Communication | CAN, RS485-115200, Ethernet. Optional: Wi-Fi, cellular, LAN |
|---|
Specifications are subject to change without notice. Images are for reference only.